Supremacy Series
®
Reach-Ins Service and Installation Manual
For customer service, call (800) 733-8829 or (800) 723-8948, Fax (989) 773-3210, www.deleld.com
18
Supremacy Series
®
Reach-Ins Service and Installation Manual
19
For customer service, call (800) 733-8829 or (800) 723-8948, Fax (989) 773-3210, www.deleld.com
WIRING DIAGRAM SUPREMACY FREEZER 115/208-230
MECHANICAL CONTROLS
THERMOSTAT
ERC2
YELLOW
BLUE
WHITE
PURPLE
BLACK
WHITE
WHITE
WHITE
WHITE
WHITE
BLACK
CR
COND
FRAME HEATER
1 PER DOOR OPENING
DS2
EVAP. FAN(S)
HLS
ELS
BALLAST
FLUORESCENT LAMP
PSS
LI
N
G
2 & 3-DOOR
MODELS
ONLY
BLUE
YELLOW
BROWN
WHITE
BLACK
WHITE
PURPLE
BROWN
YELLOW
BLACK
BROWN
TIMER RELEASE
SOLENOID
DEFROST
HEATER
BLUE
DS1
INTERIOR LIGHT
DLFD
RED
BROWN
L2
RED
BLACK
BLUE
CR COMPRESSOR RELAY
PSS POWER SUPPLY SWITCH
HLS HIGH LIMIT SAFETY
COND CONDENSING UNIT
ELS EXTERNAL LIGHT SWITCH
LPC LOW PRESSURE CONTROL
DS DOOR SWITCH
DLFD DEFROST LIMIT FAN DELAY
NOTE: Display lights are on “G” models only. Solenoid valve on remote
models only. Power cord may or may not be provided. Power switch used
with electronic controls only.
CR CR
RED
BLACK
BLUE
PARAGON
8145-008
BROWN
BLACK
FACTORY DEP SWITCH SETTING
DEF. 40 MINUTES (MAX) EVERY 6 HOUR
ELECTRONIC CONTROLS
THERMOSTAT
ERC2
2-3-DOOR
MODELS
ONLY
BLUE
YELLOW
BLACK
WHITE
PURPLE
WHITE
PURPLE
BROWN
YELLOW
BLACK
WHITE
BROWN
BLACK
YELLOW
CYCLE TIME
DEFROST
X
P2
CR
P3
DEFROST
ON LED
DEFROST
INITIATE
DEFROST
LINE NO.
COMP
LINE NO.
AEROTRONICS
P1
N
TIMED RELEASE
SOLENOID
PARAGON
8145-008
BROWN
BLUE
BROWN
BROWN
BLUE
BROWN
1 DOOR
MODELS
ONLY
Kommentare zu diesen Handbüchern